Attribute | Value |
---|---|
Product Category: | |
Manufacturer: | TE Connectivity |
Manufacturer Part Number: | TE Connectivity 2-36153-4 |
Series: | PIDG |
Connector Type: | Ring Tongue |
Voltage: | 300 V |
Stud Size: | #10 |
Orientation: | Offset |
Operating Temperature Range: | 105 °C, 221 °F |
Wire Size: | 1186 CMA, 20 AWG, .5 - .6 mm² |
Barrel Type: | Closed |
Insulated: | Yes |
Product: | Rings & Spades |
Terminal Angle: | Straight |
SKU: | AMP2-36153-4 |
Plating Material: | Copper / Tin |
Inspection Slot: | No |
Weight per Piece: | .796 g |
Stripe Color: | Red |
Number of Holes: | 1 |
Military Part Class: | Class I |
Wire Insulation Diameter (Max): | 2.79 mm / .11 in |
Wire Insulation Diameter: | 1.17 - 2.79 mm / .046 - .11 in |
Overall Length: | 23.01 mm / .91 in |
Stud Diameter: | 5 mm / .197 in |
Tongue Thickness: | .79 mm / .031 in |
Government Qualified: | Yes |
Wire Insulation Support: | With |
Heavy Duty: | No |
Wire/Cable Type: | Regular Wire |
Sealable: | No |
Shape Description: | RING-042 |
Support Style: | Insulation Restriction |
Part Alias: | 8202607913 |
2-36153-4
Specifications
Detailed Description
Enhance your electrical connections with our PIDG R IR 20 10 terminal. Designed for reliable performance, this ring tongue connector features a closed barrel and is insulated for added safety. With a voltage rating of 300V and a stud size of #10, it's perfect for various applications. The offset orientation and straight terminal angle make installation easy, while its 20 AWG wire size compatibility ensures a secure fit. Operating temperature range of 105 °C to 221 °F guarantees durability. RoHS compliant and supplied by our Rings & Spades product line, this terminal is a must-have for your connector needs.
Frequently Bought Together
Product | Part # | Description | Stock |
---|---|---|---|
![]() | TE Connectivity 1658621-1 | 10 NOVO MIL/CTR 15DP,LEAD FREE | ![]() |
![]() | TE Connectivity 2-111196-2 | 60 RCPT SYSTEM 50, LEAD FREE | ![]() |
![]() | TE Connectivity 2-36161-4 | TERMINAL,PIDG R IR 10 10 | ![]() |
![]() | TE Connectivity 208497-2 | CMC RECEPTACLE ASSY,SIZE 22 | ![]() |
![]() | TE Connectivity 3-640620-2 | 02P MTA100 CONN ASSY F/T RED | ![]() |
![]() | TE Connectivity 323916 | TERMINAL,PIDG R 26-22 8 | ![]() |
![]() | TE Connectivity 35653 | SPLICE,N CE 22-10 | ![]() |
![]() | TE Connectivity 51863-4 | TERMINAL,PIDG R IR 18 6 | ![]() |
![]() | TE Connectivity 52274 | TERMINAL,PIDG R IR 16 4 | ![]() |
![]() | TE Connectivity 52962 | TERMINAL,PG SPR SPD 12-10 8 | ![]() |
![]() | TE Connectivity 60851-3 | FASTON 250 FLAG REC 12-10 AWG TPBR | ![]() |
![]() | TE Connectivity 86286-1 | KEYING PLUG | ![]() |
![]() | TE Connectivity NB14494001 | NB14494001 VERSAFIT-3/8-0-SP | ![]() |
Product Change Notice
Effective Date | Description of Change | Download | |||
---|---|---|---|---|---|
11/29/2023 | PCN-23-176037 - Please be aware of an upcoming colorant material change to the listed part numbers. Reference performance test data: Test Report available on request. | Download | |||
06/24/2022 | P-22-022863 - New specification. TE has removed all Class 2 MIL-SPEC references from product labels and literature for the products listed in this PCN( affected products ).Any affected products shipped on or after April 13th,2022 must not be used for applications that specifically require NAVAIR Class 2 qualified product until further notice.The affected products still meet the performance specifications of AS7928 and can continue to be used in commercial applications that do not require NAVAIR Class 2 qualified product.TE Class 1 products remain active on the NAVAIR Class 1 QPL and can continue being used for applications requiring NAVAIR Class 1 qualified product.TE AS7928 Class 2 products were removed from QPL-7928(Class 2) Supplemental Information Sheets for Qualified Products Lists(QPLs), effective April 13, 2022.Since Class 2 parts must be ordered by the manufacturer s standard part number, TE standard package labels indicated both the commercial(standard TE) part number and the applicable MIL-SPEC reference(s). | Download | |||
06/04/2022 | P-22-022863 - New specification. TE has removed all Class 2 MIL-SPEC references from product labels and literature for the products listed in this PCN( affected products ).Any affected products shipped on or after April 13th,2022 must not be used for applications that specifically require NAVAIR Class 2 qualified product until further notice.The affected products still meet the performance specifications of AS7928 and can continue to be used in commercial applications that do not require NAVAIR Class 2 qualified product.TE Class 1 products remain active on the NAVAIR Class 1 QPL and can continue being used for applications requiring NAVAIR Class 1 qualified product.TE AS7928 Class 2 products were removed from QPL-7928(Class 2) Supplemental Information Sheets for Qualified Products Lists(QPLs), effective April 13, 2022.Since Class 2 parts must be ordered by the manufacturer s standard part number, TE standard package labels indicated both the commercial(standard TE) part number and the applicable MIL-SPEC reference(s). | Download | |||
02/27/2015 | E-14-014715 - Product Improvement. | Download |